Roth Geothermal Heat Pumps Water-to-Water and Water-to-Air units

About |  Products |  Literature |  Contact |  Search 

Heat Pumps-Water-to-Air and Water-to-Water

Roth Geothermal Heat Pumps Water-to-Air and Water-to-Water Units
Overview

Fundamentally, geothermal systems work differently than ordinary heating and cooling systems. Conventional systems have to produce heat by burning some type of fuel, typically propane, natural gas or fuel oil. Geothermal systems don't create heat; instead they collect and distribute it.


The earth's natural heat is collected in the winter by a series of pipes called a loop system. Fluid circulating in the loop system carries this heat to the home, where it is compressed and released to raise the inside temperature.


In the summer, this process is reversed in order to cool the home. Heat is drawn from the home, rejected to the loop and absorbed by the earth. The result is a comfortable home all year round.

Since most of the energy used for heating and cooling is free from the earth, geothermal systems are the most efficient and environmentally friendly systems on the market today.

 

Please check out the International Ground Source Heat Pumps Association at www.igshpa.okstate.edu/index.htm for more information


Characteristics

 

Roth Geothermal Heat Pumps Water-to-Air Units

TerraStar Water-to-Air RVT series
The RV-Series employs two-stage compressor technology to deliver unsurpassed comfort to your home.


Unit Features at a Glance

  • 5 Sizes: 026, 038, 050, 062, 073
  • Digital Controls
  • Coated Air Coils For Extended Life
  • ECM Blower Motors
  • Corrosion-Proof, Stainless Steel, Drain Pan
  • Copper Coaxial Water Heat Exchanger
  • High Efficiency Copeland UltraTech

Scroll Compressor

  • Optional Desuperheater
Roth Geothermal Heat Pumps Water-to-Water Units

TerraStar Water-to-Water RWT-series
Perfect for radiant floor, snow-melt, and many more applications.


Unit Features at a Glance

  • (Single-Stage): 5 Sizes: 026, 034, 046, 058, 070 (Two-Stage): 3 Sizes: 092, 120, 144
  • Optional Matched Hydronic Air Handlers
  • Digital Controls
  • Copper Coaxial Water Heat Exchanger
  • High Efficiency Single or Two Copeland
    Scroll Compressors
  • Optional Desuperheater

 


Specifications

Water-to-Air

Roth Geothermal Heat Pumps Water-to-Air and Water-to-Water Units Schematics

Model
Dimensional Data
Supply Air Return Air Water Loop
 
A
B
C
D
E
F
G
H
I
J
IN
OUT
026 50.25 22.0 25.5 0.75 1.7 2.4 14.0 12.0 28.2 20.7 3/4" 3/4"
038 54.25 26.0 30.5 0.75 1.7 2.4 14.0 16.0 30.2 25.7 3/4" 3/4"
050 60.25 26.0 30.5 0.75 1.8 2.4 16.0 16.0 34.2 25.7 1.0" 1.0"
062 60.25 28.0 30.5 0.75 1.7 2.4 16.0 16.0 34.2 25.7 1.0" 1.0"
073 60.25 28.0 30.5 0.75 1.7 2.4 16.0 16.0 34.2 25.7 1.0" 1.0"
                         

Water-to-Water

 

Single Compressor Units
Model Dimensional Data Ground Loop Load Loop Weight
  A B C IN OUT IN OUT  
RW026 20 22 32 0.75" 0.75" 0.75" 0.75" 200
RW034 24 26 34 1" 1" 1" 1" 280
RW046 24 26 34 1" 1" 1" 1" 300
RW058 24 26 36 1" 1" 1" 1" 350
RW070 24 26 36 1" 1" 1" 1" 350

 

Dual Compressor Units
Model Dimensional Data Ground Loop Load Loop Weight
  A B C IN OUT IN OUT  
RW092 24 30 48 1" 1.25" 1" 1.25" 550
RW120 24 30 48 1" 1.5" 1" 1.5" 670
RW144 24 30 48 1" 1.5" 1" 1.5" 670

 


Accessories
Roth Double O-ring hose kit for Geothermal Heat Pumps Double O-Ring Hose Kit
Roth Dual Pump Composite Flow Center for Geothermal Heat Pumps Dual Pump Composite Flow Center
Roth Single Pump Composite Flow Center for Geothermal Heat Pumps Single Pump Composite Flow Center
Roth Swivel Adapter for Geothermal Heat Pumps Swivel Adapter in 1"or 0.75"
Emerson Thermostat for Geothermal Heat Pumps Emerson Thermostat
Roth Unit Pad for Geothermal Heat Pumps Unit Pad available in plastic or foam